Oil Sampling & Analysis

Transformer Oil Sampling & Analysis
The analysis and diagnosis of mineral oil and other fluids such as natural esters, is internationally recognised as a low cost and valuable non-invasive aid in determining the condition of electrical equipment.
Utilising our experienced field teams, WILSON TRANSFORMER COMPANY can provide a comprehensive sampling and diagnostic service for all fluid filled equipment, including transformers, on-load tap changers, circuit breakers and equipment that uses SF6 gas.
It is critical that samples are taken by skilled technicians and are free from contamination to ensure that the integrity of the sample is not compromised. As such, all fluid samples are taken with a glass syringe for moisture and DGA (in accordance with IEC 60567) and a one litre bottle for other tests. SF6 samples are taken using a purposed built evacuated stainless steel container.
The samples are then sent to TJ|H2b Analytical Services, a NATA certified laboratory, for comprehensive analysis and diagnosis.
TJ|H2b have pioneered specialised proprietary condition-based diagnostics that have been proven in hundreds of thousands of tests worldwide, saving customers millions of dollars in increased reliability of supply, lower maintenance costs and prevention of catastrophic failures.
Wilson Transformer's technicians also specialise in taking paper and pressboard samples from accessible locations within transformers to test the strength and, hence, remaining life of the cellulose insulating systems and then undertaking the re-papering of locations from which the samples have been taken.
Contact:
- Oil and SF6 gas Sampling
- P: +61 3 8768 6800
- E: Email
- Oil and SF6 gas Testing
- P: +61 3 9574 9467
- E: Email
- W: www.tjh2b.com
Wilson Transformer Company is certified to ISO 19001 Quality Management, AS4801 Health & Safety and ISO 14001 Environmental Management. Read more >>
Wilson Transformer Quick Links
Products
- Large Power Transformers (> 30 MVA, ≤ 550 MVA)
- Medium Power Transformers (≤ 30 MVA)
- Ground Mounted Transformers (≤ 5 MVA)
- Pole Mounted Transformers
- Compact MV Substations
- Furnace & Rectifier Transformers
- Fault Current Limiter
- Environmental & Fire Resistant Transformers
- Special Applications
- Monitoring & Control Solutions
Contact Us
Wilson Transformer Company
310 Springvale Rd, Glen Waverley
Victoria Australia 3150
Phone +61 3 9560 0411
Fax: +61 3 9560 0599